This document specifies a general laboratory test method for determining, under defined climatic conditions, the area-specific emission rate of volatile organic compounds (VOCs) emitted by newly manufactured construction products or furnishing items, with possible application to aged products. It applies to various emission test chambers and allows the results obtained to be used to calculate VOC concentrations in a model room (Table B.1). The method is also applicable to wood-based panels and other construction products for determining the formaldehyde emission rate. In principle, it may be extended to the study of gaseous emissions from construction products and furnishing items.