Comparative evaluation of simplified pipe sizing methods for non-looped domestic water distribution systems in a Belgian context.

Domestic water distribution systems must be properly sized to ensure adequate hydraulic performance, water quality, comfort and energy efficiency. Oversizing may cause stagnation and bacterial growth (e.g. Legionella), while undersizing can lead to insufficient flow rates. Additionally, inappropriate sizing increases water waste and energy losses, especially in hot water systems.

In Belgium, the only normative approach currently available for pipe sizing is the simplified method defined in EN 806-3:2006. However, this method presents several limitations, notably a lack of clarity regarding its application domain and underlying assumptions, which may explain its limited use. As a result, designers often rely on alternative methods developed in neighbouring countries.

This study analyses and compares several simplified pipe sizing methods in order to assess their behaviour and identify their strengths and limitations. The analysed methods were selected from a broader review of international approaches, based on their relevance for practical application in Belgium. The analysis focuses on simplified methods intended for practical design use, in contrast to more detailed hydraulic calculation methods.

The analysed methods include EN 806-3:2006, DTU 60.11:2013, ISSO 55:2023 and SSIGE W3:2013. The methods are applied to representative residential building configurations, focusing on non-looped (tree-shaped) systems. DIN 1988-300:2012 is included as a detailed hydraulic reference to support the interpretation of results.

The results reveal significant discrepancies between methods, particularly for distribution pipes. Systematic trends are observed, with some methods tending to recommend larger diameters, while others recommend smaller diameters. Methods based on pressure constraints generally result in larger diameters under low-pressure conditions compared to velocity-based approaches.

Within the scope of the analysed cases, none of the analysed simplified methods achieved a satisfactory balance between simplicity, applicability and hydraulic reliability, highlighting the need for an improved simplified sizing approach.